No reset to "0" necessary, as measuring element is only loaded during the tightening process
receptacle for interchangeable plug-in tools
QuickRelease safety lock
Flash adjustment by easy-to-operate clamping lever in the handle
ergonomically shaped, non-slip adjustment element with thumb recess
optimised ball handle for fatigue-free working
double stop signal
double scale N-m/ft-lb or N-m/in-lb
on request also available as N-m version only without double scale
Left-hand tightening by turning over the plug-in tools
Further loads after triggering or loads against the functional direction, e.g. with stuck screws, do not affect the triggering mechanism, which is thus protected against damage
Calibration with the perfectControl® calibration device no. 7794 or the calibration system no. 7706. If necessary, readjustment without disassembly